Please use this identifier to cite or link to this item: http://univ-bejaia.dz/dspace/123456789/15234
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBennacer, Lila-
dc.contributor.authorBelloul, Bahia-
dc.contributor.authorBourouina, Mustapha ;promoteur-
dc.date.accessioned2021-05-06T09:38:24Z-
dc.date.available2021-05-06T09:38:24Z-
dc.date.issued2020-10-25-
dc.identifier.urihttp://hdl.handle.net/123456789/15234-
dc.descriptionSpécialité : Chimie analytiqueen_US
dc.description.abstractDans ce travail on a utilisé la planification des expériences, qu’est une méthode statistique utilisée pour développer, améliorer et optimiser les procédés d’adsorption. Cette méthodologie comporte trois étapes, la réalisation des expériences, la modélisation de la réponse par régression mathématique et l’optimisation. L’avantage de la (PE) est de réduire le nombre d’essais pour l’évaluation de plusieurs paramètres et leurs interactions. Il existe plusieurs types des plans d’expériences, parmi ces plans, on a utilisé un plan factoriel complet et un plan factoriel fractionnaire. Dans la première partie, on a appliqué un plan factoriel complet pour modéliser le procédé d’adsorption de phénol. Les trois paramètres étudiés sont : la concentration initiale de phénol, la masse de charbon actif et la granulométrie de charbon qui influent sur l’adsorption. La signification des facteurs et leurs interactions ont été évaluées à l'aide de l'analyse des variances (ANOVA), comme a été vérifié l'importance des effets et de leurs interactions sur le pourcentage d'élimination du phénol. L’équation du modèle est : Y = 80,429 - 8,115 Ci + 11,890 mads + 9,422 Ci* mads- 1,283 Ci*dp - 1,986 mads *dp + 2,136 Ci*mads*dp. Les valeurs optimales des facteurs étudiés sont : la concentration initiale de phénol 200 mg /l, la masse de charbon actif 3 g/l et le diamètre de la granulométrie 0,0475 mm le taux d’élimination maximal de phénol est 94,7594%. Dans la deuxième partie, on a appliqué un plan factoriel fractionnaire pour modéliser le procédé d’adsorption de cuivre (II). Quatre variables ont été étudiés ; la masse de l’adsorbant, le pH de la solution, la concentration des ions de cuivre et le temps de contact. La signification des facteurs et leurs interactions ont été évaluées à l'aide de l'analyse des variances (ANOVA). L’équation du modèle obtenu s’écrit comme suit : Y = -46,10 + 15,2 pH + 196,2 mads - 22,21 pH*mads + 15,31 Ct Pt. Les valeurs optimales des paramètres étudiés sont : pH=6, mads=0,6 g/50ml quel que soit la valeur de la concentration initiale et le temps de contact le taux d’élimination de cuivre est de 94,41% In this work we used design of experiments, which is a statistical method used to develop, improve and optimize adsorption processes. This methodology has three stages, carrying out the experiments, modeling the response by mathematical regression and optimization. The advantage of (DOE) is to reduce the number of tests for the evaluation of several parameters and their interactions. There are several types of experimental designs; among them, a full factorial design and a fractional factorial design were used. In the first part, we applied a full factorial design to model the phenol adsorption process. The three parameters studied are: the initial concentration of phenol, the mass of activated carbon and the particle size of the carbon which influence the adsorption. The significance of the factors and their interactions were evaluated using analysis of variances (ANOVA), as the significance of the effects and their interactions on the percentage of phenol elimination was verified. The model equation is: Y = 80,429 - 8,115 Ci + 11,890 mads + 9,422 Ci* mads- 1,283 Ci*dp - 1,986 mads *dp + 2,136 Ci*mads*dp The optimal values of the factors studied are: the initial concentration of phenol 200 mg / l, the mass of activated carbon 3 g / l and the diameter of the grains 0.0475 mm. The maximum phenol removal rate is 94.7594%. In the second part, we applied a fractional factorial design to model the copper (II) adsorption process. Four variables were studied; the mass of the adsorbent, the pH of the solution, the concentration of copper ions and the contact time. The significance of the factors and their interactions were assessed using analysis of variance (ANOVA). The resulting model equation is written as follows: Y = -46,10 + 15,2 pH + 196,2 mads - 22,21 pH*mads + 15,31 Ct Pt. The optimal values of the parameters studied are: pH = 6, mads = 0.6 g / 50ml whatever the value of the initial concentration and contact time the rate of copper removal is 94.41%.en_US
dc.language.isofren_US
dc.publisherUniversité Abderahmane MIRA de Bejaiaen_US
dc.subjectPlan d'éxperiences : ANOVA : Optimisation : Adsorption : Charbon actif : Polluanten_US
dc.titleModelisation et optimisation des procedes d’adsorption du phenol et de cuivre par les plans des experiencesen_US
dc.typeThesisen_US
Appears in Collections:Mémoires de Master



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.