Please use this identifier to cite or link to this item:
http://univ-bejaia.dz/dspace/123456789/17806
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Slimani, Nawel | - |
dc.contributor.author | Tighzer, Tinhinane | - |
dc.contributor.author | Tamalouzt, Salah ; promoteur | - |
dc.contributor.author | Djoudi, Oualid ; co-promoteur | - |
dc.date.accessioned | 2022-01-18T11:01:35Z | - |
dc.date.available | 2022-01-18T11:01:35Z | - |
dc.date.issued | 2021 | - |
dc.identifier.uri | http://hdl.handle.net/123456789/17806 | - |
dc.description | Option : ELECTROMECANIQUE | en_US |
dc.description.abstract | Ce travail de master est dédié à la commande directe en puissance améliorée basée sur la logique floue d’un redresseur en courant triphasé. Ou on a cité les problèmes liés aux perturbations ou distorsions harmoniques des réseaux électriques. Cette pollution causée principalement par les charges non-linéaires. Les convertisseurs statiques, surtout les redresseurs à diodes et à thyristors sont de nature non-linéaire. Ils requirent donc une attention particulière afin de réduire leurs harmoniques en courant. Ce travail apporte une contribution à la commande directe en puissance basée sur la théorie des puissances instantanées actives et réactives. Cette stratégie de commande a été développées, simulées et validés dont le but commun est d’obtenir un réglage performant de la tension du bus continu et un prélèvement de courants sinusoïdaux. De plus, elle été combinée avec une commande dite avancée, comme les approches floues. La simulation de toutes ces méthodes a été mise en œuvre à l’aide du logiciel Matlab/Simulink. This master’s work is dedicated to enhanced direct power control based on fuzzy logic. Or have cited the problems related to disturbances or harmonic distortions of electrical networks. This pollution caused mainly by non-linear loads. Static converters, especially diode and thyristor rectifiers, are non-linear in nature. They therefore require special attention in order to reduce their current harmonics. This work contributes to direct power control, based on the theory of instantaneous active and reactive powers. This control strategy has been developed, simulated and validated the common goal of which is to obtain an efficient regulation of the voltage of the DC bus and a sampling of sinusoidal currents. In addition, it is combined with a so-called advanced command, such as fuzzy approaches. The simulation of all these methods was implemented using Matlab/Simulink software. | en_US |
dc.language.iso | fr | en_US |
dc.publisher | Université A.MIRA-BEJAIA | en_US |
dc.subject | Commande directe : Logique floue : Redresseur triphasé | en_US |
dc.title | Commande directe en puissance améliorée, basée sur la logique floue d’un redresseur triphasé en courant | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Mémoires de Master |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Commande directe en puissance améliorée, basée sur la logique floue d’un redresseur triphasé en courant.pdf | 7.99 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.