Please use this identifier to cite or link to this item:
http://univ-bejaia.dz/dspace/123456789/18337
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lamari, Nassima | - |
dc.contributor.author | Ouaribi, Dyhia | - |
dc.contributor.author | Hamoudi, Farid ; promoteur | - |
dc.date.accessioned | 2022-02-23T09:05:20Z | - |
dc.date.available | 2022-02-23T09:05:20Z | - |
dc.date.issued | 2021 | - |
dc.identifier.uri | http://hdl.handle.net/123456789/18337 | - |
dc.description | Option : Commande Electrique | en_US |
dc.description.abstract | Le travail présenté dans ce mémoire s’intéresse à l'étude d'une technique de compensation, via un filtre actif de type T, à base d'un onduleur de tension à trois niveaux. Il a pour objectif de réduire et d'éliminer les perturbations causées par des charges non linéaires. L'identification des courants de références, le contrôle de la tension du bus continu et le contrôle des courants injectés par l’onduleur ont été élaborés. Pour l'identification, nous avons développé la méthode des puissances instantanées, grâce à une PLL (Boucle à verrouillage de phase) qui nous permet d'avoir une bonne identification de la séquence directe fondamentale des tensions perturbées. Pour le contrôle de l'onduleur, nous avons utilisé la commande par Modulation de Largeur d’Impulsion (MLI) à fin d'engendrer des courants opposants aux harmoniques polluants. Finalement une simulation a été faite avec des résultats satisfaisants. The work presented in this dissertation focuses on the study of a compensation technique, via an active T-type filter, based on a three-level voltage inverter. Its objective is to reduce and eliminate disturbances caused by non-linear loads. The identification of reference currents, the control of the DC bus voltage and the control of the currents injected by the inverter have been developed. For the identification, we developed the method of instantaneous powers, thanks to a PLL (Phase Locked Loop) which allows us to have a good identification of the fundamental direct sequence of the disturbed voltages. For the control of the inverter, we used the pulse width modulation (PWM) control in order to generate currents opposing the polluting harmonics. Finally, a simulation has been done with satisfactory results. | en_US |
dc.language.iso | fr | en_US |
dc.publisher | Université abderrahmane mira-Béjaia | en_US |
dc.subject | Commande : Mode glissant : Filtre actif multi niveaux | en_US |
dc.title | Commande par mode glissant d’un filtre actif multi niveaux de type T | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | Mémoires de Master |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Commande par mode glissant d’un filtre actif multi niveaux de type T.pdf | 2.13 MB | Adobe PDF | View/Open |