Please use this identifier to cite or link to this item: http://univ-bejaia.dz/dspace/123456789/25234
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChalane, Sahra-
dc.contributor.authorBenslimane, Zahra-
dc.contributor.authorHamoudi, Farid ; promoteur-
dc.date.accessioned2024-12-22T12:41:33Z-
dc.date.available2024-12-22T12:41:33Z-
dc.date.issued2024-
dc.identifier.urihttp://univ-bejaia.dz/dspace/123456789/25234-
dc.descriptionSpécialité : RESEAUX ELECTRIQUESen_US
dc.description.abstractL’énergie électrique est normalement fournie sous une forme de tension parfaitement sinusoïdale d’amplitude et de fréquence constantes. Mais de nos jours, à cause de la prolifération de la connexion au réseau des charges non linaires, la situation est devenue très préoccupante car ces charges déforment la tension et génèrent des harmoniques, donc alors la qualité de l’énergie dans les installations électriques se dégrade continuellement. Les charges non linéaires absorbent des courants non sinusoïdaux et consomment généralement de la puissance réactive. Grâce à l’évolution de l’électronique de puissance, des dispositifs de filtrage modernes des harmoniques auto adaptables, appelés filtrages actifs ont pu être conçus. Dans ce travail, une étude de modélisation et de commande d’un système PV connecté au réseau électrique est présentée. Le système PV composé d’un générateur PV qui fonctionne à sa puissance maximale utilisant un convertisseur continu-continu (DC-DC) commandé par un algorithme MPPT de type conductance incrémentielle (IncCond) et un onduleur continu-alternatif (DC-AC) triphasé commandé par un régulateur flou est présenté. Les résultats obtenus par simulation avec le logiciel MATLAB ont montré que le système permet d’améliorer d’une manière considérable le rendement des installations PV raccordées au réseau électrique Electrical energy is normally supplied in a perfectly sinusoïdal voltage form of constant amplitude and frequency. But nowadays, due to the proliferation of the connection to the network of non-linear loads, the situation has become very worrying because these loads distort the voltage and generate harmonics, therefore the quality of energy in electrical installations deteriorates. Nonlinear loads draw non-sinusoidal currents and generally consume reactive power. Thanks to the evolution of power electronics, modern self- adapting harmonic filltering devices, called active filtering, have been able to be designed. In this work, a modeling and control study of a PV system connected to the electrical network is presented. The PV system consists of a PV generator that operates at its maximum power using a direct-to-direct (DC-DC) converter controlled by an incremental conductance (IncCond) MPPT algorithm and a three-phase direct-to-alternating (DC-AC) inverter. Controlled by a fuzzy regulator is presented. The results obtained by simulation with MATLAB software showed that the system makes it possible to considerably improve the efficiency of PV installations connected to the electrical networken_US
dc.language.isofren_US
dc.publisherUniversité Abderrahmane mira-Béjaiaen_US
dc.subjectSystème photovoltaique connecté : Réseau : Filtre actif : Système PV : Commandeen_US
dc.titleModélisation et simulation d’un système photovoltaïque connecte au réseau à travers un filtre actifen_US
dc.typeThesisen_US
Appears in Collections:Mémoires de Master



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.