dc.descriptionSpécialité : Installations Energétiques et Turbomachinesen_US
dc.description.abstractNotre étude qui porte, sur l'analyse exergétique de la centrale à cycle combiné gaz-vapeur Ras-Djinet dont les capacités de production est de 1131,1 MW, l’étude menée dans ce travail consiste en l’ambition d’élaborer un diagnostic énergétique pour la centrale en question, pour objectif d'évaluer les pertes exergétiques et leur source. Dans la première partie de notre travail, une présentation détaillée a été effectuée à la centrale de Ras-Djinet, en mettant en évidence ses caractéristiques techniques et ses principales composantes afin de mieux comprendre l'architecture et les processus techniques de la centrale. Dans un deuxième lieu, nous avons adopté l’approche énergétique et exergétique ou on examine les outils et les méthodologies d'analyse associés Au bout de notre travail, nous avons calculé le rendement et la perte exergétique de chaque composant de la centrale, ainsi que sa perte et son rendement global.En outre, des suggestions ont été proposées, en fin de notre mémoire, afin de réduire les pertes et améliorer le rendement exergétique Our study focuses on the exergy analysis of the Ras-Djinet combined cycle gas-steam power plant, which has a production capacity of 1131.1 MW. The aim of this study is to develop an energy diagnostic for the power plant in order to evaluate exergy losses and their sources. In the first part of our work, a detailed presentation of the Ras-Djinet power plant was conducted, highlighting its technical characteristics and main components to better understand the architecture and technical processes of the plant. In the second part, we adopted an energy and exergy approach where we examined the associated tools and analysis methodologies. At the end of our study, we calculated the overall exergy efficiency and losses for each component of the power plant, as well as its overall loss and efficiency. Furthermore, suggestions were proposed in the conclusion of our thesis to reduce losses and improve exergy efficiencyen_US
dc.language.isofren_US
dc.publisherUniversité Abderahmanr Mira Bejaiaen_US
dc.subjectCycle combiné : Exergie : Irréversibilités : Production d’énergie : Chaudière de récupérationen_US
dc.titleAnalyse Exergétique De La Centrale A Cycle Combiné Gaz-Vapeur De Ras-Djinet 1131 MWen_US
dc.typeThesisen_US
Appears in Collections:Mémoires de Master

Files in This Item:
File Description SizeFormat 
Analyse Exergétique De La Centrale A Cycle Combiné Gaz-Vapeur De Ras-Djinet 1131 MW.pdf2.84 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.