Please use this identifier to cite or link to this item: http://univ-bejaia.dz/dspace/123456789/23967
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHammouche, Yanni-
dc.contributor.authorLaidi, Tinhinan-
dc.contributor.authorZembouai, Idris;promoteur-
dc.date.accessioned2024-07-01T10:32:03Z-
dc.date.available2024-07-01T10:32:03Z-
dc.date.issued2023-
dc.identifier.urihttp://univ-bejaia.dz/dspace/123456789/23967-
dc.descriptionOption: Génie de l'environnementen_US
dc.description.abstractLe travail réalisé au cours de cette étude s’inscrit dans le cadre général de traitement des eaux usées de la station de Bougie plage de la ville de Béjaïa. Le principe de l’épuration de la station, est le traitement biologique par boues activées à faible charge en aération prolongée. Le travail effectuée au sein de la station, consiste à l’étude de fonctionnement de la chaine de traitement des eaux usées de la STEP, et l’évaluation des paramètres physicochimique et biologique dont (T (°C), pH, CE (µS/cm), MES (mg/l), DBO5 (mg/l)), ainsi, l’analyse des boues d’épurations par le teste de décantation de la boue biologique et l’analyse de taux Siccité de boue produite. Les résultats de l’analyse de la température et du potentiel hydrogène, sont conformes aux normes de rejets algériens et de l’OMS. Par contre, les résultats de l’analyse de la CE, les MES et la DBO5 sont au-delà des normes de rejet, ce qui interprète l’existence d’un mauvais fonctionnement dans le traitement, donc il est important de détecter rapidement les problèmes de la station d'épuration et de les résoudre dès que possible. The work carried out during this study is part of the general framework of wastewater treatment at the Bougie Plage station in the city of Béjaïa. The principle of purification of the station, is the biological treatment by activated sludge at low load in prolonged aeration. The work carried out within the station consists of the study of the operation of the wastewater treatment chain of the STEP, and the evaluation of the physico-chemical and biological parameters including (T (°C), pH, EC (µS/cm), MES (mg/l), BOD5 (mg/l)), thus, the analysis of sewage sludge by the settling test of biological sludge and the analysis of dryness rate of sludge produced. The results of the temperature and hydrogen potential analysis comply with Algerian and WHO discharge standards. On the other hand, the results of the EC, MES and BOD5 analysis are beyond the rejection standards, which interprets the existence of a malfunction in the treatment, so it is important to quickly detect the sewage treatment plant problems and solve them as soon as possible.en_US
dc.language.isofren_US
dc.publisherUniversité Abderahmane MIRA de Bejaiaen_US
dc.subjectaux usées : Traitement des eaux : STEP : Boues activées : Paramètres physico chimiqueen_US
dc.titleTraitement Des Eaux Usees Par Boues Activée Exemple De La STEP De Bougie Plageen_US
dc.typeThesisen_US
Appears in Collections:Mémoires de Master

Files in This Item:
File Description SizeFormat 
Traitement Des Eaux Usees Par Boues Activee Exemple De La STEP De Bougie Plage.pdf8.16 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.