dc.description.abstract |
Cette étude évalue les performances de la station d'épuration des eaux usées de l'unité
CO.G.B de Bejaia en analysant divers paramètres indicateurs de la pollution. Les résultats montrent
certaines non-conformités aux normes réglementaires, notamment en ce qui concerne les matières
en suspension. Cependant, les analyses des matières grasses respectent les normes. Les valeurs de
pH varient à l'entrée de la station, mais sont conformes à la sortie. Les demandes chimique et
biochimique en oxygène sont non-conformes avant l'ensemencement, mais se rapprochent des
normes après. Les sulfates et les nitrates respectent les normes à la sortie de la station grâce aux
traitements mis en place. La station utilise également des processus spécifiques pour réduire la
concentration des métaux lourds. Ce mémoire, montre que le traitement des eaux usées industrielles
est un défi complexe, qui nécessite une approche intégrée et une évaluation régulière des
technologies existantes. Nous pensons que les résultats de cette étude pourraient être utiles pour
les entreprises et les décideurs impliqués dans la gestion des eaux usées industrielles, afin de
promouvoir des pratiques plus durables et respectueuses de l'environnement.
This study evaluates the performance of the wastewater treatment plant at the CO.G.B unit
in Bejaia by analyzing various pollution indicator parameters. The results indicate certain noncompliance with regulatory standards, particularly regarding suspended solids. However, the
analysis of fats complies with the standards. The pH values vary at the plant's inlet but are
compliant at the outlet. The chemical and biochemical oxygen demands are non-compliant before
seeding but approach the standards afterwards. Sulfates and nitrates comply with the standards at
the plant's outlet due to the implemented treatments. The plant also employs specific processes to
reduce heavy metal concentrations. This study demonstrates that industrial wastewater treatment
is a complex challenge requiring an integrated approach and regular evaluation of existing
technologies. We believe that the results of this study could be useful for businesses and decisionmakers involved in industrial wastewater management, promoting sustainable and
environmentally-friendly practices. |
en_US |
dc.language.iso |
fr |
en_US |
dc.publisher |
Université Abderahmane MIRA de Bejaia |
en_US |
dc.subject |
Pollution, Etation : ’Epuration, MES, DBO5, DCO, Ensemencement, métaux lourds. |
en_US |
dc.title |
Traitement Des Eaux Usées De La Station D’épuration Des Corps Gras Bejaia CO.G.B)Labelle Par Utilisation D’un Procédé D’ensemencement |
en_US |
dc.type |
Thesis |
en_US |